COLD ROOM EQUIPMENT · AACORE SUPPLY
Equipment for cold rooms

Monoblock & split units. For cold rooms.

Monoblock and split units for chilled cold rooms and freezer rooms. Compare published room volumes in m³, understand the installation options and buy your selected model at HVAC Spare Parts.

MONOBLOCK / INTARCONMonoblock unit for chilled cold rooms · INTARCON MCV-LD-0009A
Chilled storageMCV-LD-0009A
5 m³Published volume
01   Monoblock & Split02   Chilled storage & Frozen storage03   Published volume · m³04   HVAC Spare Parts →
Equipment

Find your refrigeration unit

Start with your application and installation type.

534 units

Prices read from HVAC Spare Parts and updated manually. Options selected in the store may change the final amount.

Indicative volume under the manufacturer’s selection conditions. Volume alone does not replace a heat load calculation.

Selection criteria

Monoblock and split units by application

Compare monoblock and split units within the application you need. Published m³ provide an initial shortlist, to be checked against the actual cold room conditions.

Monoblock or split

Two configurations. One informed choice.

The difference is how the components are arranged and where heat is rejected.

Monoblock unit for freezer rooms · KIDE EMB0004L1P

Monoblock

The compressor, condenser and evaporator form one compact assembly, with the indoor and outdoor sections separated by the cold room wall or ceiling.

  • Compact wall or ceiling assembly
  • Follow ventilation and mounting requirements
  • Check panel thickness and openings
Explore monoblocks →
Split unit for freezer rooms · INTARCON BSH-NG-0018A

Split

The condensing unit and evaporator are separate, connected by refrigerant piping. Heat rejection can be located away from the cold room.

  • More flexibility in positioning
  • Refrigerant connections between units
  • Check pipe runs, height differences and supply
Explore split units →
Choosing a unit

Volume is the start.
Conditions make the choice.

Two cold rooms with the same volume may need different units. Check these four factors before choosing.

01 /

Operating temperature

Chilled storage and frozen storage are different duties. Use the application stated for the exact model.

02 /

Insulation and ambient

Panel thickness and condition, outdoor temperature and condenser ventilation affect the load and performance.

03 /

Products and door openings

Product quantity, incoming temperature and door opening frequency change the cooling demand.

04 /

Installation and power

Check voltage, frequency, condensate drainage and service clearance. For a split unit, also check the refrigerant piping.

Calculate internal volume

Enter the usable internal dimensions of your cold room. This filters the catalogue; it does not size the refrigeration capacity.

10 m³
AACORE SUPPLY

Guides to choosing cold room units

Understand mounting, room volume, temperature and operation before selecting a model.

FAQ

Before choosing your unit

Chilled storage or frozen storage?

Units for chilled products and units for frozen products are selected for different operating temperatures. Matching nominal room volume does not make them interchangeable.

Can I choose by volume alone?

No. Check room and ambient temperatures, insulation, stored products, door openings and the manufacturer’s selection conditions.

Does a monoblock need installation?

Yes. Mounting, power supply, condensate drainage and ventilation must follow the manufacturer’s instructions.

Where do I complete my purchase?

Each unit links to its exact product page at HVAC Spare Parts, where you can check options, applicable taxes and complete your order.

Is room volume the same as airflow?

Room volume is expressed in m³. Fan airflow is expressed in m³/h. They are different quantities.